Temperature Sensor Resistance to Voltage Calculator
Convert sensor resistance and temperature data into a 0–5 V input calibration table. Enter low/high points and choose an interpolation method, or paste the full resistance table supplied with your sensor. This calculates expected input voltage; it does not create a physical voltage signal.
Calculated calibration table
CSV is a reference table; confirm the required format before importing into ECU software.
Table methods: Linear resistance joins the two resistance endpoints with a straight line, then converts each point through the voltage divider. Linear voltage joins the endpoint voltages. NTC beta estimates a thermistor curve. Supplied points converts each resistance directly with no curve-fitting. Neither two-point interpolation nor beta fitting recreates a full manufacturer curve exactly.
Formula and assumptions
Signal voltage = supply × sensor resistance ÷ (pull-up resistance + sensor resistance). Example: 5 × 8,026 ÷ (1,000 + 8,026) = 4.44604 V. Pull-up inferred from a known pair = sensor resistance × (supply ÷ measured voltage − 1). For NTC beta: B = ln(Rlow/Rhigh) ÷ (1/Tlow − 1/Thigh), and R(T) = Rlow × exp[B × (1/T − 1/Tlow)], using kelvin.